Skip to content

The Review step

Step two of the planner: the six views the computed plan is read through, and the chart and readouts of the Overview view.

Updated View as Markdown

The Review step is the plan as the planner computed it. The step rail will not advance to it until the plan describes a dive that can be computed; if no schedule could be produced, a red banner names the reason.

The six views

View Answers
Overview, below What shape is this dive, and what does it come to?
Schedule What do I actually do, minute by minute?
Gas Consumption Do I have enough gas, and where does it run out?
Tissue Saturation Which compartment is driving the ascent?
Settings What exactly did I ask the planner for?
GF Calibration What did the second model say? Thalmann GF Calibration only.

Settings lists the levels, the gases, and one titled group per configuration card of the Plan step: the same listing the finalized plan’s printed report carries. See Finalizing and sharing.

Overview

The dive drawn as a chart, readouts beneath it. A legend names the two traces: Depth, coloured by the gas being breathed, and Deco Ceiling, the shallowest depth the model would permit at that moment; where the two meet you are at a stop. A control beside the legend opens the chart full-screen.

A 45 m dive for 25 minutes on 21/35: depth against the decompression ceiling

Six readouts sit below the chart: Max Depth, Runtime, TTS (time to surface, decompression included), First Stop on a dive that has one, O₂ CNS with a fill bar that turns amber at 80 % and red at 100 %, and OTU. Reference: outputs defines each. On a dive that follows another, a Repetitive Dive Series card joins them; see Repetitive dives.

Scenarios

A plan with scenarios grows a Scenarios picker at the left of the bar above every view except Settings and GF Calibration; the plan’s name, time to surface and runtime sit at its right, and on a narrow screen the picker comes first. On closed circuit each entry is one open-circuit ascent on one subset of your bailout gases, the first being the Loop, the dive you intend to make; on either circuit, Contingency overruns join the picker, grouped under headings carrying their numbers.

One scenario is selected at a time. Every view recomputes for it, the chart draws it over the loop as a dashed line in place of the ceiling trace, and the warnings swap onto its own. See Bailout scenarios.

Next

The schedule view takes the same dive as a stop list.

Navigation

Type to search…

↑↓ navigate↵ selectEsc close